F G 077


FG00077
PARTS-SERVICE
March 1, 1998
R30ES
GRAM
SUBJECT: Directional Contactor Retro-Fit
For units prior to B174H03008U experiencing intermittent loss of traction due to contaminated tips, a new
directional contactor is now available to resolve this problem. Some minor wiring changes and mounting
modifications will have to be made to use the new contactor assembly. Follow the instructions below.
Parts list
Quantity Part Number Description
1 1454116
Contactor
4 3004500
Connectors
1. Remove the current GE directional contactor assembly, be sure to retain the self tapping mounting screws.
2. Locate the Curtis directional contactor assembly as shown in the above picture.
3. Drill two 1/4 inch mounting holes and use the self taping screws to mount the contactor assembly.
4. Clip off the ring terminal ends from directional control wiring (wires 6, 6A, 8, 8A, 24 and 25).
5. Crimp on the new spade terminal ends onto control wiring (wires 6, 6A, 8, 8A, 24 and 25).
6. Hook up the main power cables as shown in above diagram.
We reserve the right to make changes in design or add improvements without incurring the obligation to make such changes in
equipment previously manufactured.


Wyszukiwarka

Podobne podstrony:
077 NEWPHASE
I F 077
2010 01 02, str 077 080
KLIR biuletyn 077
v 04 077
076 077
076 077
Lesson Plan 077 Text
075 077
07786
077 Motyw Wenus w malarstwie
077 080
v 02 077
074 077

więcej podobnych podstron