5441337441

5441337441



M. Lazar et al.


Designing Low Gas Flow Meters Based on the Calometric Principle...

Device the most commonly used principle to detect flow in gases and liąuids using microsensors is based on the concept of a thermal flow sensor that was first postulated by Thomas in 1911. The basie principle is shown in Fig. 1 in which the heat transferred per unit time from a resistive wire heater to a moving liąuid is monitored at two points via thermocouple temperaturę sensors [1],

THOMAS CYLINDER DESIGN

The developed Thomas cylinder (TC), used for measuring the flow ratę of gaseous fluid, is a device using calorimetric principle of flow ratę measuring (Fig. 1).

The most important element of TC is a kanthal coil with reguladable output providing energy input to the flowing fluid by transforming electrical energy into heat.

Sensing element of the device consists of the concentrically situated thermocouples which are placed in the specified distances from the electric coil.

Insulation of foam polyethylene


Figurę 1. 3D view of finał Thomas cylinder design Slika 1. 3D prikaz konstrukcije Thomasova eilindra

When a steady State has been achieved, the transferred amount of heat to the flowing medium (nitrogen) by the electric coil (Kanthal resistance wire) with a thickness of 0.5 mm may be expressed by the foli owi ng equation

Q = m-cr-{T2-T,) (J)    (1)

where are:

w - the mass of the gas overflow through TC (kg),

cp - heat capacity of gas at constant pressure (J-kg^-K'1),

T\ - inlet temperaturę of TC (K), r2 - outlet temperaturę of TC (K)

The Holłstic Approach to Environment 1(2011)4,153-162 Page 154



Wyszukiwarka

Podobne podstrony:
M. Lazar et al. Designing Low Gas Flow Meters Based on the Calometric Principle... REFERENCES 1.
M. Lazar et al. Designing Low Gas Flow Meters Based on the Calometric Principle... The relationship
M. Lazar et al. Designing Low Gas Flow Meters Based on the Calometric Principle... total output prov
M. Lazar et al. Designing Low Gas Flow Meters Based on the Calometric Principle... The temperaturę d
M. Lazar et al. Designing Low Gas Flow Meters Based on the Calometric Principle... Yohunetric flow r
M. Lazar et al. Designing Low Gas Flow Meters Based on the Calometric Principle... Theoretical corre
M. Lazar et al. Designing Low Gas Flow Meters Based on the Calometric Principle... The constant of
M. Lazar et al. Designing Low Gas Flow Meters Based on the Calometric Principle... DISCUSSION As fol
Designing Low Gas Flow Meters Based on the Calometric Principle... ISSN 1848-0071 Preliminary
526 M. Daszykowski et al.Step 4: Normalization To take other deficiencies of the assessed herbal fin
NETFLIX FONT PSYGHOLOGY Fonts have different characteristics associated with them. Flow does typogra
al creatures 29 Dragon Puffl Use shading on the dragon s body to make him look morę lifelike. L
707svc 06 jul. i*o»>CIRCUIT DESCRIPTIONS TR-707 and TR-727 are designed based on the same Circuit
152 J. Ohnishi et al. Fig. 3. Cross-sectional view of a newly designed sex-tupole magnet. X(cm) Fig.
165 K. Inoue et al. drical ceramic. We are also designing another disk-type RF window. We will test
Zdjęcie169 STŁLWATER/profil/ Meters Zonę Subzone McCallum et al (1980) Senes Symbol Megacyclic

więcej podobnych podstron